Const VOLUME = "C:\"
Const CONTEXT = "ClientAccessible"
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set objShadowStorage = objWMIService.Get("Win32_ShadowCopy")
errResult = objShadowStorage.Create(VOLUME, CONTEXT, strShadowID)
Const VOLUME = "C:\"
Const DIFFERENTIAL_VOLUME = "E:\"
Const MAXIMUM_SPACE = 130023424
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set objShadowStorage = objWMIService.Get("Win32_ShadowStorage")
errResult = objShadowStorage.Create(VOLUME, DIFFERENTIAL_VOLUME, MAXIMUM_SPACE)
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * From Win32_ShadowCopy")
For Each objItem in colItems
objItem.Delete_
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * From Win32_ShadowStorage")
For Each objItem in colItems
objItem.Delete_
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ShadowCopy")
For Each objItem in colItems
Wscript.Echo "ID: " & objItem.ID
Wscript.Echo "Client accessible: " & objItem.ClientAccessible
Wscript.Echo "Count: " & objItem.Count
Wscript.Echo "Device object: " & objItem.DeviceObject
Wscript.Echo "Differnetial: " & objItem.Differential
Wscript.Echo "Exposed locally: " & objItem.ExposedLocally
Wscript.Echo "Exposed name: " & objItem.ExposedName
Wscript.Echo "Exposed remotely: " & objItem.ExposedRemotely
Wscript.Echo "Hardware assisted: " & objItem.HardwareAssisted
Wscript.Echo "Imported: " & objItem.Imported
Wscript.Echo "No auto release: " & objItem.NoAutoRelease
Wscript.Echo "Not surfaced: " & objItem.NotSurfaced
Wscript.Echo "No writers: " & objItem.NoWriters
Wscript.Echo "Originating machine: " & objItem.OriginatingMachine
Wscript.Echo "Persistent: " & objItem.Persistent
Wscript.Echo "Plex: " & objItem.Plex
Wscript.Echo "Provider ID: " & objItem.ProviderID
Wscript.Echo "Service machine: " & objItem.ServiceMachine
Wscript.Echo "Set ID: " & objItem.SetID
Wscript.Echo "State: " & objItem.State
Wscript.Echo "Transportable: " & objItem.Transportable
Wscript.Echo "Volume name: " & objItem.VolumeName
Wscript.Echo
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ShadowStorage")
For Each objItem in colItems
Wscript.Echo "Volume: " & objItem.Volume
Wscript.Echo "Allocated space: " & objItem.AllocatedSpace
Wscript.Echo "Differential volume: " & objItem.DiffVolume
Wscript.Echo "Maximum space: " & objItem.MaxSpace
Wscript.Echo "Used space: " & objItem.UsedSpace
Wscript.Echo
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ShadowProvider")
For Each objItem in colItems
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "CLSID: " & objItem.CLSID
Wscript.Echo "ID: " & objItem.ID
Wscript.Echo "Type: " & objItem.Type
Wscript.Echo "Version: " & objItem.Version
Wscript.Echo "Version ID: " & objItem.VersionID
Wscript.Echo
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ShadowStorage")
For Each objItem in colItems
objItem.MaxSpace = 500000000
objItem.Put_
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ShadowContext")
For Each objItem in colItems
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "Client accessible: " & objItem.ClientAccessible
Wscript.Echo "Differential: " & objItem.Differential
Wscript.Echo "Exposed locally: " & objItem.ExposedLocally
Wscript.Echo "Exposed remotely: " & objItem.ExposedRemotely
Wscript.Echo "Hardware assisted: " & objItem.HardwareAssisted
Wscript.Echo "Imported: " & objItem.Imported
Wscript.Echo "No auto release: " & objItem.NoAutoRelease
Wscript.Echo "Not surfaced: " & objItem.NotSurfaced
Wscript.Echo "No writers: " & objItem.NoWriters
Wscript.Echo "Persistent: " & objItem.Persistent
Wscript.Echo "Plex: " & objItem.Plex
Wscript.Echo "Transportable: " & objItem.Transportable
Wscript.Echo
Next